Uji Performansi Sistem Thermal Storage Akibat Penyetelan Superheat Adjuster pada TXV

Performance Test of The Thermal Storage System Effect to The Superheat Adjuster Setting at The TXV

Tugas Akhir, 022 / 2020 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2021-12-07 09:50:03
Oleh : Regina Agustin - 171611024 (regina.agustin.tptu17@polban.ac.id)
Dibuat : 2021-12-07, dengan 4 file

Keyword : Performance Test, Thermal, Storage System, Effect, Superheat, Adjuster Setting, TXV
Subjek : Uji Performansi, Sistem, Thermal Storage, Akibat Penyetelan, Superheat, Adjuster, TXV

Thermal storage adalah sebuah tempat penyimpanan media pendingin yang dilakukan secara tidak langsung (indirect system) pada sistem refrigerasi. Dimana evaporator yang berisi refrigeran R22 (refrigerant primer) digunakan untuk mendinginkan larutan NaCl (14%) sebanyak 50 liter di dalam thermal storage yang nantinya bertugas sebagai refrigeran sekunder. Larutan refrigeran sekunder tersebut akan disirkulasikan menggunakan pompa untuk mendinginkan apel sebanyak 4 kg yang ada di kabin dengan temperatur -1°C. Setelah larutan refrigeran sekunder mencapai -10°C thermal storage akan mengalami cut off dan pompa akan tetap berjalan untuk mendinginkan apel hingga temperatur apel tercapai. Pada tugas akhir ini dilakukan pengujian untuk membandingkan performansi sistem thermal storage terhadap penyetelan sudut putar superheat adjuster pada TXV sebesar 0°, 30° searah jarum jam dan 30° berlawanan arah jarum jam. Hal tersebut dilakukan untuk mengetahui putaran superheat adjuster yang paling efektif untuk sistem. Hasil dari penelitian yang dilakukan yaitu nilai rata-rata COP aktual dan COP Carnot pada variasi putaran superheat adjuster sebesar 0°, 30° searah jarum jam dan 30° berlawanan arah jarum jam masing-masing adalah 3,48 dan 4,81, 3,40 dan 4,56, 3,39 dan 5,32. Nilai efisiensi pada masing-masing sebesar 72,4%, 74,5% dan 63,7%. Besar daya listrik pada masing-masing adalah 459 Watt, 499,8 Watt dan 447,1 Watt. Besar superheat pada masing-masing adalah 6,33 K, 8,85 K dan 4,08 K. Nilai chilling time pada masing-masing selama 324 menit, 293 menit dan 343 menit. Dari hasil perhitungan dan analisis didapatkan bahwa putaran yang efektif pada sistem ini berada pada putaran 30° searah jarum jam.

Deskripsi Alternatif :

Thermal storage is a storage place for cooling media that is carried out indirectly (indirect system) in the refrigeration system. Where the evaporator containing R-22 refrigerant (primary refrigerant) is used to cool 50 liters of NaCl (14%) in thermal storage which will later serve as secondary refrigerant. The secondary refrigerant solution will be circulated using a pump to cool 4 kg of apples in the cabin with a temperature of -1 ° C. After the secondary refrigerant solution reaches -10 ° C, the thermal storage will experience a cut off and the pump will continue to run to cool the apples until the temperature of the apples is reached. In this final project, a test was conducted to compare the performance of the thermal storage system to the adjustment of the superheat adjuster at the TXV of 0 °, 30 ° clockwise and 30 ° counterclockwise. This is done to determine the most effective superheat adjuster rotation for the system. The results of this research are the mean value of the COP actual and the COP Carnot on the variation of the superheat adjuster rotation of 0 °, 30 ° clockwise and 30 ° counterclockwise, respectively 3.48 and 4.81, 3.40 and 4.56 and 3.39 and 5.32. The efficiency values were 72.4%, 74.5% and 63.7%, respectively. The amount of electric power in each is 459 Watt, 499.8 Watt and 447.1 Watt. The superheat values for each were 6.33 K, 8.85 K and 4.08 K. The chilling time values were 324 minutes, 293 minutes and 343 minutes, respectively. From the results of calculations and analysis, it is found that the effective rotation of this system is 30 ° clockwise.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: A. P. Edi Sukamto, S.T., M.T.


    Pembimbing 2: Triaji Pangripto Pramudantoro, S.T., M.Eng., Editor: Muhammad Abdillah Islamy, S.Pd

Download...