Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Refrigerasi & Tata Udara > Program Studi Teknik Pendingin & Tata Udara > 2020

Uji Kinerja Thermoelectric Water Cooler Tipe CL-200 Akibat Perubahan Beban Pendinginan

Performance Test Thermoelectric Water Cooler Type CL-200 Due To Changes Of Cooling Load

Tugas Akhir, 024 / 2020 / RTU
Undergraduate Theses from JBPTPPOLBAN / 2021-12-09 09:36:04
Oleh : Risal Alissalam - 171611026 (risalalissalam07@gmail.com)
Dibuat : 2021-12-09, dengan 4 file

Keyword : Thermoelectric water cooler, water mass flow rate, cooling capacity, power consumption, COP
Subjek : Water cooler thermoelectric, laju aliran massa air, kapasitas pendinginan, konsumsi daya, COP

Sistem thermoelectric water cooler merupakan suatu sistem refrigerasi yang memanfaatkan air sebagai media yang didinginkan. Penelitian ini bertujuan untuk mendapatkan performansi pada sistem thermoelectric water cooler. Thermoelectric water cooler ini divariasikan laju aliran massa air dan kecepatan fan agar dapat dilihat performansi dari thermoelectric water cooler. Alat yang digunakan untuk penelitian ini adalah water cooler tipe CL-200. Dalam pelaksanaan tugas akhir ini ada 9 variasi perubahan beban pendinginan pada 3 variasi bukaan valve dan 3 variasi kecepatan fan dengan cara mengubah posisi bukaan valve dan kecepatan fan. Dibandingkan dengan variasi bukaan valve dan kecepatan fan yang lain, COP (Coefficient Of Performance) pada bukaan valve 3 dengan kecepatan fan 100% memiliki nilai COP paling tinggi. Nilai COP thermoelectric water cooler dapat diketahui dengan melakukan pengolahan data debit air, kecepatan air, laju aliran massa air, kapasitas pendinginan dan konsumsi daya. Hasil dari uji kinerja ini menunjukkan bahwa nilai kapasitas pendinginan bukaan valve 1 dengan variasi kecepatan fan 50% sebesar 0,034 KW sedangkan bukaan valve 3 dengan variasi kecepatan fan 100% sebesar 0,085 KW. Nilai konsumsi daya bukaan valve 1 dengan variasi kecepatan fan 50% sebesar 66,6 watt sedangkan bukaan valve 3 dengan variasi kecepatan fan 100% sebesar 76,8 watt. Nilai COP pada bukaan valve 1 dengan variasi kecepatan fan 50% yaitu sebesar 0,507 sedangkan bukaan valve 3 dengan variasi kecepatan fan 100% yaitu sebesar 1,107.

Deskripsi Alternatif :

The thermoelectric water cooler system is a refrigeration system that uses water as the cooled medium. This study aims to obtain the performance of the thermoelectric water cooler system. The thermoelectric water cooler varies the mass flow rate of water and fan speed so that the performance of the thermoelectric water cooler can be seen. The tool used for this research is the CL-200 type water cooler. In the implementation of this final project, there are 9 variations of cooling load changes in 3 variations of valve openings and 3 variations of fan speed by changing the position of the valve opening and fan speed. Compared with other variations of valve openings and fan speeds, COP (Coefficient Of Performance) at valve opening 3 with 100% fan speed has the highest COP value. The COP value of the thermoelectric water cooler can be determined by processing data on water discharge, water velocity, water mass flow rate, cooling capacity and power consumption. The results of this performance test indicate that the value of the cooling capacity of valve opening 1 with a fan speed variation of 50% is 0.034 KW, while the valve opening 3 with a fan speed variation of 100% is 0.085 KW. The value of the power consumption of valve opening 1 with a fan speed variation of 50% is 66.6 watt, while valve opening 3 with a fan speed variation of 100% is 76.8 watt. The COP value at valve opening 1 with a fan speed variation of 50% is 0.507, while the valve opening 3 with a fan speed variation of 100% is 1.107.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTPPOLBAN
Organisasi
Nama KontakErlin Arvelina
AlamatJl. Trsn. Gegerkalong Hilir Ds. Ciwaruga
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon022 201 3789 ext. 168, 169, 239
Fax022 201 3889
E-mail Administratorerlin.arvelina@polban.ac.id
E-mail CKOerlin.arvelina@polban.ac.id

Print ...

Kontributor...

  • Pembimbing 1: Ir. Windy Hermawan Mitrakusuma, M.T.


    Pembimbing 2: Ir. Arda Rahardja Lukitobudi, M.Eng., Editor: Muhammad Abdillah Islamy, S.Pd

Download...