Path: Top > Tugas Akhir - D3 > 2017 > Jurusan Teknik Refrigerasi & Tata Udara > Program Studi Teknik Pendingin & Tata Udara > 2020
Kaji Eksperimental Kinerja 15% Sodium Chloride dan 15% Calcium Chloride sebagai Refrigeran Sekunder pada Thermal Storage untuk Penyimpanan Tomat
Experimental Study on the Performance of 15% Sodium Chloride and 15% Calcium Chloride as Secondary Refrigerants in Thermal Storage for Tomato Storage
Tugas Akhir, 054 / 2020 / RTUUndergraduate Theses from JBPTPPOLBAN / 2021-12-20 10:29:45
Oleh : Safira Eva Dini - 171611060 ( safira.eva.tptu17@polban.ac.id )
Dibuat : 2021-12-20, dengan 4 file
Keyword : Experimental Study, Performance, Sodium Chloride, Calcium Chloride, Secondary Refrigerants, Thermal Storage, Tomato Storage
Subjek : Kaji, Eksperimental, Kinerja, Calcium Chloride, Refrigeran Sekunder, Thermal Storage, Penyimpanan, Tomat
Mesin pendingin yang hanya menggunakan refrigeran primer dalam proses pendinginannya akan menyebabkan rentang waktu cut-off yang singkat, sehingga konsumsi energi listrik akan menjadi besar.Penggunaan refrigeran sekunder pada thermal storage dinilai dapat mengatasi hal tersebut. Refrigrran sekunder yang digunakan pada thermal storage untuk tugas akhir ini yaitu 15% sodium chloride dan 15% calcium chloride karena dinilai aman serta mudah didapatkan. Kemudian untuk proses pengambilan data diawali dengan pemvakuman, pengisian refrigeran R22, selanjutnya pengambilan data menggunakan refrigeran sekunder sodium chloride, jika data yang didapatkan belum benar maka dilakukan pengulangan sampai data benar, selanjutnya dapat dilakukan pengambilan data menggunakan calcium chloride. Hasil pengolahan data dari beberapa parameter untuk sodium chloride yaitu chilling time kabin 255 menit, chilling time produk 339 menit, ratarata waktu cut-off 109 menit, rata-rata COPa 3,25, efisiensi 75%, dan konsumsi energi listrik sebesar 2,06 kWh. Sedangkan hasil pengolahan data dari calcium chloride yaitu chilling time kabin 243 menit, chilling time produk 252 menit, ratarata waktu cut-off 191 menit, rata-rata COPa 3,23, efisiensi 74,1%, dan konsumsi energi listrik sebesar 1,86 kWh. Berdasarkan hasil perbandingan enam parameter tersebut dapat dikatakan bahwa calcium chloride lebih baik dari sodium chloride dilihat dari konsumsi energi listrik sedangkan dari segi efisiensi sistem sodium chloride lebih baik dari calcium chloride
Deskripsi Alternatif :The use of secondary refrigerants in thermal storage aims to maintain the cabin temperature during conditions cut-off , so that the consumption of electrical energy used is smaller. Secondary refrigerants used in thermal storage for this final project are 15% sodium chloride and 15% calcium chloride because they are considered safe and easy to obtain. Then for the data collection process begins with vacuuming, charging the refrigerant R22, then data retrieval using the secondary refrigerant sodium chloride, if the data obtained is not correct, then it is repeated until the data is correct, then data retrieval can be done using calcium chloride. The results of data processing from several parameters for sodium chloride are chilling time of cabin255 minutes, chilling time productof 339 minutes, average cut-off time of 109 minutes, average COPa of 3.25, efficiency of 75%, and consumption of electrical energy of 2.06 kWh. While the results of data processing from calcium chloride are chilling time of cabin 243 minutes, chilling time productof 252 minutes, an average cut-off time of 191 minutes, an average COPa of 3.23, an efficiency of 74.1%, and an electrical energy consumption of 1.86. kWh. Based on the results of the comparison of the six parameters, it can be said that calcium chloride is better than sodium chloride in terms of electrical energy consumption, while in terms of system efficiency, sodium chloride is better than calcium chloride.
Beri Komentar ?#(1) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- Pembimbing 1: Triaji Pangripto Pramudantoro, S.T., M.Eng.
Pembimbing 2: Ir. Windy Hermawan Mitrakusuma, M.T., Editor: Muhammad Abdillah Islamy, S.Pd
Download...
File : KELENGKAPAN TA - 171611060.pdf
(628639 bytes)
File : BAB 1 - 171611060.pdf
(280424 bytes)
File : BAB 2 - 171611060.pdf
(342730 bytes)
File : BAB 5 - 171611060.pdf
(277067 bytes)