Pengaruh Hambatan Aliran Udara Pada Kondenser Terhadap Performansi AC Split 1 PK
The Effect Of Air Flow Resistance On The Condenser On Performance Of 1 PK Split AC
Research Report from JBPTPPOLBAN / 2024-02-16 14:05:49Oleh : Triaji Pangripto Pramudantoro - 196002221984031002 (triajipangripto@polban.ac.id)
Dibuat : 2022-02-03, dengan 1 file
Keyword : aliran udara kondenser, perawatan AC split
Perawatan yang kurang baik akan mengakibatkan performansi mesin A/C split akan menurun seperti indoor unit menjadi kurang dingin, mesin sering mengalami trip, kompresor menjadi overheat dan kemungkinan akan berdampak pula terhadap pemborosan konsumsi energi yang digunakan yang ditandai dengan peningkatan arus listrik yang terpakai. Beberapa kasus yang sering ditemui pada mesin A/C berkapasitas kecil yang kurang perawatan diantaranya: sirip pada outdoor unitnya kotor karena debu yang menempel, adanya barang/benda yang dapat menghalangi aliran udara, sirip pada outdoor sudah rapuh sehingga rontok atau bahkan melipat sehingga menutup laju aliran udara dsb. Terganggunya aliran udara pada bagian outdoor tersebut selanjutnya akan berdampak terhadap performansi unit A/C split, khususnya terhadap laju pendinginan, tekanan kerja, Coeficient of performance dan konsumsi energi listrik. Tujuan dari penelitian ini adalah untuk mengetahui korelasi/dampak dari hambatan aliran udara pada outdoor unit terhadap performansi mesin dan besarnya perubahan/peningkatan konsumsi energi listriknya. Metode yang dilakukan adalah dengan cara membandingkan performansi mesin yang normal tanpa terganggu aliran udara pada outdoor unitnya dibandingkan terhadap mesin yang aliran udara outdoor unitnya mengalami hambatan. Dimulai dengan diberi hambatan berturut turut sebesar 1/6, 1/8 dan1/4 dari luas permukaan kondenser. Dari kajian tersebut terbukti bahwa hambatan aliran udara pada kondenser dapat berakibat merugikan kinerja sistem AC Split, terbukti seperti terjadinya hal sebagai berikut: Kenaikan temperatur kerja sistem, kenaikan tekanan discharge (11,67%) dan tekanan suction (11,49%), kenaikan konsumsi daya listrik hingga 9,3%, penurunan kinerja sistem (Coeficient of Performance) dari 4,63 hingga 3,70 dan penurunan efek refrigerasi hingga 6,52%.
Deskripsi Alternatif :Poor maintenance will result in the performance of the split A/C engine being reduced decreases as the indoor unit becomes less cold, the engine often trips, the compressor overheats and may also have an impact on wastage energy consumption used which is characterized by an increase in electric current that used. Some cases that are often encountered in small capacity A/C engines that are less maintenance including: the fins on the outdoor unit are dirty due to dust attached, the presence of items / objects that can block the flow of air, the fins on the outdoor are already fragile so that it falls out or even folds so that it closes the air flow rate, etc. Disruption of air flow in the outdoor section will then have an impact on on the performance of the split A/C unit, especially on the cooling rate, working pressure, Coeficient of performance and consumption of electrical energy. The purpose of this study is to determine the correlation/impact of flow resistance air in the outdoor unit on engine performance and the amount of change/increase consumption of electrical energy. The method used is by comparing normal engine performance without disturbing the air flow in the outdoor unit compared to machines whose outdoor unit airflow is blocked. Starting with a given resistance successively equal to 1/6, 1/8 and 1/4 of the surface area condenser. From this study it is evident that the airflow resistance in the condenser can be result in detrimental to the performance of the Split AC system, as evidenced by the following occurrences: Increase in system working temperature, increase in discharge pressure (11.67%) and pressure suction (11.49%), increase in electric power consumption up to 9.3%, decrease in system performance (Coeficient of Performance) from 4.63 to 3.70 and a decrease in refrigeration effect to 6.52%.
Beri Komentar ?#(0) | Bookmark
Properti | Nilai Properti |
---|---|
ID Publisher | JBPTPPOLBAN |
Organisasi | |
Nama Kontak | Erlin Arvelina |
Alamat | Jl. Trsn. Gegerkalong Hilir Ds. Ciwaruga |
Kota | Bandung |
Daerah | Jawa Barat |
Negara | Indonesia |
Telepon | 022 201 3789 ext. 168, 169, 239 |
Fax | 022 201 3889 |
E-mail Administrator | erlin.arvelina@polban.ac.id |
E-mail CKO | erlin.arvelina@polban.ac.id |
Print ...
Kontributor...
- , Editor: Erlin Arvelina
Download...